brocade-01:admin> switchshow
switchName: brocade-01
switchType: 170.0
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 5
switchId: fffc05
switchWwn: 10:00:85:36:46:ea:d4:b4
zoning: ON (default)
switchBeacon: OFF
HIF Mode: OFF
Index Port Address Media Speed State Proto
==================================================
0 0 050000 id 16G Online FC F-Port 50:0a:09:80:0e:13:be:80
1 1 050100 id 16G Online FC F-Port 10:00:00:10:9b:87:45:f4
2 2 050200 id 16G Online FC F-Port 10:00:00:10:9b:87:45:f4
3 3 050300 id 16G No_Light FC
4 4 050400 id 16G No_Light FC
5 5 050500 id 16G No_Light FC
6 6 050600 id 16G No_Light FC
7 7 050700 id 16G No_Light FC
8 8 050800 id 16G No_Light FC
9 9 050900 id 16G No_Light FC
10 10 050a00 id 16G No_Light FC
11 11 050b00 id 16G No_Light FC
12 12 050c00 id 16G No_Light FC
13 13 050d00 id 16G No_Light FC
14 14 050e00 id 16G No_Light FC
15 15 050f00 id 16G No_Light FC
16 16 051000 id 16G No_Module FC
17 17 051100 id 16G No_Module FC
18 18 051200 id 16G No_Module FC
19 19 051300 id 16G No_Module FC
20 20 051400 id 16G No_Module FC
21 21 051500 id 16G No_Module FC
22 22 051600 id 16G No_Module FC
23 23 051700 id 16G No_Module FC
Run below commands to change name of the ports 0-2
portname 0 -n "SAN_SPA_FC4"
portname 1 -n "SAN_SPB_FC4"
portname 2 -n "ESX_01_HBA"
Run portname to check if port names has been applied corerctly
brocade-01:admin> portname
port 0: SAN_SPA_FC4
port 1: SAN_SPB_FC4
port 2: ESX_01_HBA
port 3: port3
port 4: port4
port 5: port5
port 6: port6
port 7: port7
port 8: port8
port 9: port9
port 10: port10
port 11: port11
port 12: port12
port 13: port13
port 14: port14
port 15: port15
port 16: port16
port 17: port17
port 18: port18
port 19: port19
port 20: port20
port 21: port21
port 22: port22
port 23: port23
Run below commands to create alias for SAN front end ports connected to switch port 0 & 1
alicreate "SAN_FE","21:00:00:34:00:3c:c2:01"
aliadd "SAN_FE", "21:00:00:34:00:3c:c2:02"
Run alishow "SAN_FE" to check if alias for SAN front end ports has been crfeated correctly
alias: SAN_FE
21:00:00:34:00:3c:c2:01
21:00:00:34:00:3c:c2:02
Run below commands to create zone to allow traffice between SAN and ESX_01, as you can see you can use wwn and/ or alias
zonecreate "ESX_01_to_SAN_FE", "21:00:00:24:ff:3c:c2:39"
zoneadd "ESX_01_to_SAN_FE", "SAN_FE"
Run zoneshow "ESX_01_to_SAN_FE" to check if zone has been created correctly
brocade-01:admin> zoneshow ESX_01_to_SAN_FE
zone: ESX_01_to_SAN_FE
21:00:00:24:ff:3c:c2:39; SAN_FE
Run switchshow to check your active configuration, on our switch it is "default"
brocade-01:admin> switchshow
switchName: brocade-01
switchType: 170.0
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 5
switchId: fffc05
switchWwn: 10:00:85:36:46:ea:d4:b4
zoning: ON (default)
switchBeacon: OFF
HIF Mode: OFF
Index Port Address Media Speed State Proto
==================================================
0 0 050000 id 16G Online FC F-Port 50:0a:09:80:0e:13:be:80
1 1 050100 id 16G Online FC F-Port 10:00:00:10:9b:87:45:f4
2 2 050200 id 16G Online FC F-Port 10:00:00:10:9b:87:45:f4
3 3 050300 id 16G No_Light FC
4 4 050400 id 16G No_Light FC
5 5 050500 id 16G No_Light FC
6 6 050600 id 16G No_Light FC
7 7 050700 id 16G No_Light FC
8 8 050800 id 16G No_Light FC
9 9 050900 id 16G No_Light FC
10 10 050a00 id 16G No_Light FC
11 11 050b00 id 16G No_Light FC
12 12 050c00 id 16G No_Light FC
13 13 050d00 id 16G No_Light FC
14 14 050e00 id 16G No_Light FC
15 15 050f00 id 16G No_Light FC
16 16 051000 id 16G No_Module FC
17 17 051100 id 16G No_Module FC
18 18 051200 id 16G No_Module FC
19 19 051300 id 16G No_Module FC
20 20 051400 id 16G No_Module FC
21 21 051500 id 16G No_Module FC
22 22 051600 id 16G No_Module FC
23 23 051700 id 16G No_Module FC
Run below command to add "ESX_01_to_SAN_FE" zone to "default" configuration
cfgadd "default", "ESX_01_to_SAN_FE"
Run below command to check if "ESX_01_to_SAN_FE zone has been succesfuly added to "default" configuration
cfgshow default
Run below command to enable new "default" configuration
cfgenable default
You should run below command to save switch configuration - only on Brocade switches with old FOS
cfgsave
We worth they developed a customized plan based on the requirements, key phrases, as well as preferred niche as opposed to simply placing plan.
ReplyDeletebest agency logos
They have been great partners to work with in terms of their ownership and overall flexibility
ReplyDeletebranding companies
Thankfulness to my dad who informed me relating to this blog, this website is really amazing.
ReplyDeleteinteraction design firms
Keep it up!! You have done the nice job having provided the latest information.
ReplyDeletedigital design agency